Physical Device eCopy Integration
To configure physical device eCopy settings, do the following:
- In Devices, select Physical Devices and select a device from the list.
 - Select eCopy in the Settings menu to enable the Add eCopy Integration option.
 - Enter a Description if necessary.
 - Select a DCE Server from the drop-down list.
 - Enter the IP Address of the eCopy server.
 - Enter the Embedded (ShareScan) IP address. This is the IP Address of the physical device (this is editable).
 - Enter the Server port number. The default port 9325 and must match the port defined on the eCopy ShareScan server for communication with the DCE server.
 - Enter the Delimiter character used to separate transaction records.
 - Enter the Connection timeout value, in milliseconds, that closes the connection if no communication with the ScanStation server is established.
 - Select Yes or No from the Send password drop-down list. When Equitrac communicates with ShareScan through the Cost Recovery protocol, determine whether password should be or not sent to ShareScan.
 - Select the eCopy version from the drop-down list. This is the protocol version of the Cost Recovery Connector.
 - Enter the TripleDES encryption key supplied by eCopy for the version 3 protocol.
 - Click Save to save the physical device eCopy settings.