General tab
Use this tab to enter the connection settings for logging in to the FileNet P8 Content Engine object store.
Option | Description |
---|---|
Activate |
Activate the component according to a condition. For more information about conditions, see Conditional fields under Appendices. |
Pass through |
Set this option to Yes to pass the original document to subsequent components in the workflow. If this option is not set to No, the component does not pass the input documents to the subsequent components in the chain. You can use conditions in this field. For more information about conditions, see Conditional fields under Appendices. If you enter an invalid condition into Pass
through box, the activation is Yes by
default.
|
Content Engine web service URL |
Enter the URL of the Content Engine web service. This URL should be in the following format:
With the following parameters:
The following example URL uses an IP address: http://192.178.223.10:9080. The Web service path, such as "/wsi/FNCEWS40MTOM/", will be automatically appended to this URL. |
User name |
Specify this value to connect to the object store in the format that is required by the FileNet P8 Content Engine. For the Directory Service or Active Directory security provider it is usually the short name (login name) of the Directory Server user. For example, FnAdmin. You can click the button to open the Select User dialog box which allows searching for the user on the FileNet P8 server. Search request will use the currently entered user name and password to connect to the server. The
button is enabled only if you have already connected to the FileNet P8
Content Engine. The first time that you connect you have to manually
enter the Content Engine web service URL,
User name and
Password.
|
Password |
Specifies the user password to connect to the object store. You cannot use RRTs in this text box. |
Obtain password via RRT |
Select this check box is you want to obtain the password from an RRT from previous components. When this check box is selected, the Password text box is disabled. The component then obtains the password from the RRT at run time to connect to the FileNet P8 Content Engine. |
Password RRT |
Enter an RRT of another component which will be used for connection to the FileNet P8 Content Engine. This field supports and returns values for encrypted by restricted RRTs. For more information, see Encrypted Field RRTs. You should never explicitly specify a password in the Password RRT text box, since the value of this field is not encrypted. At configuration time the component always uses the value of the Password text box as the user password for connection to the FileNet P8 Content Engine even if the Obtain password via RRT is selected. |
Object store |
Enter the name or identifier of the FileNet P8 Content Engine object store to route documents into. You can enter the name of the object store manually or click the button to open the Select Object Store dialog box, which allows selection of an object store. |
Target folder |
Enter the path to the target folder to route documents into. You manually enter the path preceded by the slash mark (/) character (for example, /Folder1/SubFolder2). When the Select Target Folder dialog
box opens, it expands to display the currently selected folder. However,
if the currently selected folder is invalid for the actual folders tree,
it expands as many folders in the path that it finds in the tree.
|
Create folders if not exists |
If this check box is selected, the component will create the specified folder if it does not exist. If this check box is not selected and the specified path to the target folder does not exist, the component will display an error message at run time. By default, this check box is selected. Click the button next to this check box to open New Folder Options dialog box, which allows you to set up parameters for creating the folder. If several folders are created, all of them will share the same parameters. |