General Settings
Configure the general parameters of the redaction profile on this tab.
Option |
Description |
---|---|
Activate |
Activate the profile according to a condition. For more information about conditions, see Conditional fields under Appendices. |
Name |
Enter a name for the profile. |
Execute condition |
Set the condition for profile execution in the text boxes. You should use RRTs. If a specified RRT is replaced with the same value as the one specified in the right text box, then the profile will be applied to the document. If the specific profile is selected on the General Settings tab,
then this condition will be ignored.
|
Original documents group |
This group allows you to configure the processing of original documents. |
Pass through |
Select this option to pass through the original documents to the subsequent components in the workflow. |
Output to |
Select this option to copy the original documents into the local folder. Click the browse button(...) to select the folder. |
Rename schema |
Enter the rename schema for documents. You can use RRTs in this text box. This text box is enabled only when Output to check box is selected. |
Overwrite existing files |
Check this box if you want to overwrite the copied documents if they are already presented in the output folder. This check box is enabled only when Output to check box is selected. |
Generated documents group: |
This group allows you to configure the processing of the generated documents. |
Pass through |
Select this option to pass through the generated documents to the subsequent components in the workflow. |
Output to |
Select this option to copy the generated documents into the local folder. Click the browse button (...) to select the folder. |
Rename schema |
Enter the rename schema for documents. You can use RRTs in this text box. This text box is enabled only when Output to check box is selected. |
Overwrite existing files |
Check this box if you want to overwrite the copied documents if they are already presented in the output folder. This check box is enabled only when Output to check box is selected. |
Template |
Enter the path to the template image file that will be used for defining redaction zones. |
Require specific number of pages |
Check this box if you want to specify the number of pages for profile execution. Then specify the number in the text box. The profile will be executed only when the number of pages in the input document is the same as the specified number in this text box; otherwise, the whole job will be rejected. If you select a template to be used in the
profile, then the initial value in the Require
specific number of pages text box will be
written. When you select this option, you will be allowed to
overwrite the value in the text box.
|