Physical device eCopy integration
To configure physical device eCopy settings, do the following:
- In Devices, select Physical Devices and select a device from the list.
- Select eCopy in the Settings menu and enable the Add eCopy Integration option.
- Enter a Description if necessary.
- Select a DCE Server from the drop-down list.
- Enter the IP Address of the eCopy server.
- Enter the Embedded (ShareScan) IP address. This is the IP Address of the physical device (this is editable).
- Enter the Server port number. The default port 9325 and must match the port defined on the eCopy ShareScan server for communication with the DCE server.
- Enter the Delimiter character used to separate transaction records.
- Enter the Connection timeout value, in milliseconds, that closes the connection if no communication with the ScanStation server is established.
- Select Yes or No from the Send password drop-down list. When Equitrac communicates with ShareScan through the Cost Recovery protocol, determine whether password should be or not sent to ShareScan.
- Select the eCopy version from the drop-down list. This is the protocol version of the Cost Recovery Connector.
- Enter the TripleDES encryption key supplied by eCopy for the version 3 protocol.
- Click Save to save the physical device eCopy settings.